Insulated Fire Doors Provide Protection and Thermal Efficiency

fire door

Key Product Features:

  • Insulated Steel, R-Value = 5.0
  • Standard Max Width 24’
  • Standard Max Height 24’
  • UL or FM Rated
  • Patented planetary gear design
  • Conforms to NFPA Standard 80
  • Easy drop-test and floor resettable

Options & Accessories:

  • Fire Door Release System
  • Horns and Strobes
  • Smoke Detectors
  • Vision FireLites
  • Chain Hoist, Crank or Motor Operation
  • Thru-Wall Operation
  • Bottom Bar Sensing Edges
  • Optional Powder Coat finish

Slat Profiles

See our Model 700C Slat Profiles document for more profiles and details.

slat profile
No. 34 Slat Profile

Factory Finish Colors

 

White
 

Gray
 

Beige
 

Brown

IMPORTANT NOTICE: Due to variations in computer monitors, such as resolution and color settings, this standard color chart should only be used as a general guide. If you have a job where you need to be exactly sure of the accuracy of the color shade shown, please contact a customer service representative by using the "Contact Us" link at the top of this page.

Wayne Dalton FireStar® Rolling Steel Fire Doors provide a practical and innovative solution to safety and fire protection. FireStar® doors can be drop-tested and reset at any time by anyone, such as a facility manager or maintenance supervisor, thanks to a standard auto-reset feature.

The FireStar® door features a forward-thinking design that outperforms industry standard fire doors in all areas, including auto-reset testing capability; smooth, quiet operation; and reliable, long-lasting performance.

Safety

The FireStar® door can be drop tested easily and reset in seconds; no tools or service technicians required. These tests can be done in addition to the required annual inspection by a trained technician. By self-testing throughout the year, you can be even more confident that the door will function safely in the event of fire.

The drop-out mechanism is designed to eliminate down time during drop testing while the viscous governor technology results in smoother, quieter door operation.

Reliability

The revolutionary FireStar® design uses a patent-pending planetary gear on the drop-out mechanism ensuring years of reliable service and drop-out performance. Factory tested and approved for a minimum of 20,000 cycles, the FireStar® door can be used and/or tested on a regular basis.

FireStar® fire doors have been tested and approved to meet the requirements of well-known agencies, such as Underwriters Laboratories and Factory Mutual, and conform to NFPA Standard 80.

Simplicity

Wayne Dalton incorporates one standardized component design for all FireStar® doors regardless of size, and utilizes fewer parts than other models. This helps to ensure more accurate installations and reduces the possibility of potential service calls in the future.

As an added benefit, eliminating one of the fusible link cables helps the door and surrounding area look cleaner and less cluttered. It also reduces the risk of cable interference with other nearby fixtures.